Máy đo tốc độ vòng quay Ono sokki TM-3110, Ono sokki TM-3120, Ono sokki TM-3130, Ono sokki TM-3140

Ngày đăng: 22/01/2019 - 597 lượt xem

Giá: Liên hệ
  • Xuất xứ:
  • Tình trạng:
  • Model:
  • Bảo hành:
Số lượng:

Hotline:

Hotline: 0365930441

Outline of specifications

Common specifications

Input section

Input terminal

M3 free terminal screw

Input impedance

10 kΩ or more

Input format

Voltage or non-voltage
Input amplification AC or DC
Applicable detector Electromagnetic/magneto-electric/photoelectric detector, rotary encoder, proximity switch

AC amplifier

  • Signal waveform: Sine or Square wave
  • Signal voltage range: Sine 0.2 to 45 Vrms, square wave: 0.6 V to 63 Vp-p
  • Signal frequency range: 1 Hz to 100 kHz

DC amplifier

  • Signal waveform: Square waveform having a pulse width at 5 μs or more.
  • Signal voltage range: Hi level: +4 to +30 V, Lo level:-1 to +1 V
  • Signal frequency range: 0.1 Hz to 100 kHz

Low pass filter

Selectable from OFF (100 kHz)/100 Hz/20 kHz
Pulse output section
Output voltage Hi level +4.5 V or more
Low level +0.5 V or less
Output logic Negative
Load resistance 100 kΩ or more
Output terminal M3 free terminal screw

Display

Display device Fluorescent display tube (selectable of three-stage brightness, 6-digit display)
Display refresh time Selectable from 0.2 s (factory setting), 0.4 s, 0.5 s, 0.6 s, 0.8 s, 1.0 s to 10 s (in 1.0s step).
Unit of measurement  

Calculation item

Unit

Rotation speed r/s, r/min, r/h
Circumferential speed mm/s, m/s, mm/min, m/min
Moving speed mm/s, m/s, mm/min, m/min, km/min, mm/h, m/h, km/h
Period s, min
Times (1/s) 1/s, 1/min, 1/h
Frequency Hz, kHz
Flow ml/s, ml/min, ml/h, l/s, l/min, l/h
Passing time s, min
User-defined
(Engineering unit)
EU/s, EU/min, EU/h

 

Number of decimal points Selectable from OFF (factory setting), number of decimal point of 1, 2 and 3 digit
SIG indicator Blink in synchronization with input signal
Error display Backup memory error, board error, input frequency error, display digit error, memory full error, setup value error
Calculation
Calculation display Rotation speed, circumferential speed, moving speed, period, times(1/s), frequency, flow, passing time
Measurement method Periodic calculation method
Calculation time 10 ms + 1 period time
Measurement accuracy

Display value × (±0.01 %) within ±1 count

*The display value indicates the count value except the decimal point.

Auto zero function The display value becomes zero with no signal input for the setup time in advance.

Selectable from below;
OFF (11 s), 0.5 s, 1.0 s, 2.0 s, 3.0 s, 4.0 s, 5.0 s, 6.0 s, 7.0 s, 8.0 s, 9.0 s, 10.0 s

Rapid deceleration follow-up function If an input signal rapidly decreases and there is no signal input to tachometer approx. 1 second or more, measurement automatically decelerates with this function and then zeroed in approx. 11 seconds later.
Moving average function

Selectable from below:
OFF (factory setting), 2, 4, 8, 16, 32, 64, 128

*Analog output by TM-3130/0330 is obtained by the processing of
moving average with the calculation at every 10 ms.

Peak-hold function Hold the peak value (maximum, minimum, average) between start and stop status.
Memory
Panel condition memory Memorize 4 kinds of measurement conditions.
(The setup conditions can be stored and recalled.)
Power supply for detector
Output voltage 12 VDC ±10 %
Maximum output current 100 mA
General specifications
Power rating

100 to 240 VAC (50 Hz/60 Hz)

*Cable for power supply is sold separately.

Withstand voltage 1500 VAC (1 min)
Insulation resistance 10 MΩ or more (at 500 VDC by megohhom )
Power rating
  • 11 to 19 VA (TM-3110)

  • 13 to 21 VA (TM-3120)

  • 16 to 25 VA (TM-3130)

  • 12 to 21 VA (TM-3140)

(Power rating is 20 to 30 VA when analog, BCD and
comparator output cards are equipped.)

Operating temperature range 0 to +50 °C (with no condensation)
Storage temperature range -10 to +60 °C (with no condensation)
Outer dimensions 96(W) × 48(H) × 148(D) mm
Weight Approx. 310 g
Applicable standards  
CE marking Low Voltage Directive EN61010-1: 2010 (3rd)

Overvoltage Category II/Pollution Degree 2

EMC(Electromagnetic Compatibility)Directive Embedded board type EN61326: 2006

 

Accessories Panel mounting fixtures x 1 set

 

BCD output specifications (TM-3120 and TM-0322 optional card)

Output signal

Output form

6-digit parallel output

Output format Open collector
Sink current 32 mA max.
Output withstand voltage 24 V max.

Output logic

Positive logic

Data refresh time 100 ms or less

Input signal (request signal)

Input logic

Negative logic(pulse width:10 μs or more)

Operating edge

Falling edge

Input voltage

voltage

Output mode

Mode selector

Selectable from normal or request

BCD output specifications (TM-0321 optional card)

TM-0321 card outputs BCD as voltage output. Operation is same as TM-3120 (BCD-open collector).

Output signal
Output format TTL
Output level Hi level: +3.8 to +5.25 V, Lo level: 0 to +0.4 V

Analog output specifications (TM-3130 and TM-0330 optional card)

Output signal Selectable form voltage or current
Output method 12bit D/A conversion
Output range Voltage range: Selectable from 0 to 10 V, 0 to 5 V, 1 to 5 V
Current range: 4 to 20 mA, 0 to 16 mA
Load resistance Voltage output: 100 kΩ or more
Current output: 500Ω or less
Linearity ±0.3%/F.S.
Output adjustment Voltage output: ±5 %/F.S. or more
Current output:: ±3 %/F.S. or more
Setup accuracy Voltage output: ZERO ±5 %/F.S., FULL ±5 %/F.S.
Current output: ZERO ±3 %/F.S. , FULL ±0.75 %/F.S.
Zero drift ±0.05 %/F.S./ °C
Span drift ±0.05 %/F.S./ °C
Output refresh time Selectable from followings: 10, 20, 50, 100, 200, 500 ms, 1 s

Note) Adding TM-0330 optional card enables TM-3110, 3150 and 3140 analog output having same as the above specifications.

Comparator function specifications (TM-3140 and TM-0340 optional card)

Output function UPPER, LOWER, OK, ERROR outputs

*It outputs OK signal when both UPPER and LOWER outputs are OFF.
It outputs ERROR signal when comparator has an abnormal operation.

Setup UPPER setup: 6- digit numeric input The relay is ON when UPPER ≤ displayed value.

LOWER setup: 6-digit numeric input The relay is ON when LOWER > displayed value.

Output format 1-make contact output

*Three kinds of outputs (COMP1, COMP2 and COMP3) are output independently.

UPPER, LOWER, OK, ERROR for each combination of outputs Ex.) COMP1=LOWER, COMP2=UPPER, COMP3=ERROR

Maximum contact capacity 30 VDC/1 A, 250 VAC/1 A
Output refresh time Approx. 10 ms
Reset Reset output level to be contact OFF
Automatic recover

UPPER, LOWER, or OK output
The comparator automatically recovers when the rotation speed falls under the setup level again after that the state of contact is ON at OK/UPPER/LOWER output.

*The rotation speed of recovery can be changed by using hysteresis function. Measurement range: 0 to 20 %, can be setup in 1 % step

Output hold The state of contact ON is hold unless the reset signal is input.
Shot output The time of holding the contact ON (shot time) can be changed. The state will automatically recover after the holding time.

Setup range: 10 to 2000 ms in 10 ms steps

Delay The state will be contact ON when the rotation speed exceeds continuously for the setup time or more in advance.

Setup range: OFF (0) to 1000 ms in 10 ms steps