Specifications
Two-phase square wave, phase difference: 90° ±20° Output voltage Hi:4.5 V or more / Lo:0.4 V or less
*1. When used with Ono Sokki's Gauge Counter. The values within parentheses () is the maximum spindle velocity used with the DG-4140/DG-4190/DG-5100/DG-3000. *2. An attachment may not return completely if it is facing upwards. *3. Vibration/shock resistance values described in above are not guaranteed during measurement operation. • Disconnected or modified signal cable is not applicable to CE marking NOTE:Please check an attaching portion (material, grounding etc.) before you install the New GS series. If the New GS series is installed in a metallic portion that is not grounded, it might cause blowout of a fuse or cable damage because of a potential difference that might be produced between a counter side chassis and a sensor side chassis.
Long stroke type
GS-5050A/5100A
10 µm resolution
GS-5051A/5101A
1 µm resolution
Long Stroke type
*1. When used with Ono Sokki's Gauge Counter. The values within parentheses () are the maximum spindle velocity used with the DG-4140/DG-4190/DG-5100/DG-3000. *2. An attachment may not return completely if it is facing upwards. *3. Vibration/shock resistance values described in above are not guaranteed during measurement operation. • Disconnected or modified signal cable is not applicable to CE marking.
NOTE:Please check an attaching portion (material, grounding etc.) before you install the New GS series. If the New GS series is installed in a metallic portion that is not grounded, it might cause blowout of a fuse or cable damage because of a potential difference that might be produced between a counter side chassis and a sensor side chassis.
High resolution type
GS-3813B/3830B
0.1 µm resolution
• DG-5100 Digital Gauge Counter for GS-3800 series (click)
The number of sliding times: 5 million →15 million
Protection class: IP64 → IP66G
Vibration resistance: 98 m/s2 →196 m/s2 Shock resistance: 980 m/s2 →1960 m/s2
*1. When used with Ono Sokki’s Gauge Counter. The values within parentheses () are the maximum spindle velocity used with the DG-5100. *2. An attachment may not return completely if it is facing laterally or upwards. *3. Vibration/shock resistance values described in above are not guaranteed during measurement operation. • Disconnected or modified signal cable is not applicable to CE marking. NOTE:Please check an attaching portion (material, grounding etc.) before you install the New GS series. If the New GS series is installed in a metallic portion that is not grounded, it might cause blowout of a fuse or cable damage because of a potential difference that might be produced between a counter side chassis and a sensor side chassis.