Ngày đăng: 22/57/2019 - 668 lượt xem
Hotline:
Fiber Optic Sensor Amplifier
FG-1300
Optical Fiber Sensor
FS-5500/FS-540
The FG-1300 is a non-contact type high-performance amplifier that emits red light from LED to a rotating object, and detects the variation of the reflected red light amount.
This amplifier is used in combination with an exclusive detector FS-5500*/FS-540 Optical Fiber Sensors which has adopted environment resistant design. The glass fibers are covered with flexible stainless steel tube for rotation measurement in limited space.
* FS-5500 slim type optical fiber sensor can measure an object hard to be measured and enables the measurement in the limited space, which cannot be measured with previous models.
Features of FG-1300 Fiber Optic Sensor Amplifier
Features of FS-5500 Optical Fiber Sensor
Can be detected the rotation of a small object in a limited space such as 2 mm pitch of zebra tape, turbine blades or small motor etc.
Can be used for crank angle detection that high resolution is required, for tracking analysis, and for balancing measurement. Optimal as measuring unit including FFT Analyzer or tachometer.
Since it has slim body and can be used under very low or high temperature (-40 to 250 ℃), it is possible to measure vehicle rotation (engine, shaft, gear, or drive shaft) or measure parts on production line. Even under hard conditions or at limited space, rotation or angle can be measured.
System Configuration
-Wide variety of applications for rotation measurement and analysis.-
Application examples
Presence or absence detection of small parts
FS-5500 can project to a small part at a pinpoint with φ2mm of light emission. Presence or absence of a small part flowing on a production line can easily be detected by measuring reflected light amount and judging the level of it by the threshold function.
Inspection of a missing tablet
FG-1300 checks a missing tablet by projecting light onto the production line and comparing the reflection light amount.
Overview specification
Light source: Red visible light LED Light receiving element: Phototransistor
Analog and pulse
Analog (MONITOR): Detects reflected light and outputs signal waveform in proportion to the light amount. Output voltage range: 0 to 10 V
Pulse (PULSE OUT): Output as pulse signal which has been shaped the waveform of reflected light and converted to square wave. Output voltage range: Lo level 0.5 V or less, Hi level 4.5 V or more
Signal output connector: BNC
10 k Ω (analog, pulse)
-40 to 250 °C
<Reference> Gap between the Optical Fiber Sensor and the measurement object
(When the output signal is 1 V.)
HT-011 Reflection mark(12 mm square x 25 pcs per sheet, 10 sheets/pack )
*The length of fiber cable can be extended. Please contact your nearest distributor or send