Type |
Monitor for displacement |
Monitor for velocity |
Monitor for acceleration |
VM-90 MED
(superior type) |
VM-90 MFD (standard type) |
VM-90 MEV
(superior type) |
VM-90 MFV
(standard type) |
VM-90 MEA
(superior type) |
VM-90 MFA (standard type) |
Frequency
range |
Medium |
Low |
15 to 500 Hz
+0.5dB -3dB
20 to 500 Hz
±0.5dB |
5 to 300 Hz
+0.5dB -3dB
10 to 300 Hz
±0.5dB |
|
Medium |
Low |
15 to 1,000 Hz +1dB -3dB
20 to 850 Hz ±1dB |
5 to 300 Hz +1dB -3.5dB
10 to 300 Hz ±1dB |
|
10 to 8,000 Hz ±3 dB
20 to 5,000 Hz ±1 dB |
Measurement
range
(full scale) *1 |
Select from 0 to 20 μmp-p,
0 to 50 μmp-p, 0 to 100 μmp-p,
0 to 200 μmp-p, 0 to 500 μmp-p |
Select from 0 to 1 mm / s,
0 to 2 mm / s, 0 to 5 mm / s,
0 to 10 mm / s, 0 to 20 mm / s,
0 to 50 mm / s |
Select from 0 to 1m / s2,
0 to 2m / s2, 0 to 5 mm / s2,
0 to 10 m / s2, 0 to 20m / s2,
0 to 50m / s2, 0 to 100 m / s2 |
Alarm step |
2 steps |
1 step |
2 steps |
1 step |
2 steps |
1 step |
DC output
(for recorder) |
4 to 20 mA
(at the load 0 to
300 Ω)
1 to 5 V
(100 kΩ or more, 250Ω connection
to outside |
- |
4 to 20 mA
(at the load 0 to
300 Ω)
1 to 5 V
(100 kΩ or more,
250Ω connection
to outside |
- |
4 to 20 mA
(at the load 0 to 300 Ω)
1 to 5 V
(100 kΩ or more,
250Ωconnection
to outside |
- |
Alarm action |
Activated over alarm setting value (time constant : approx. 3 seconds) |
Ararm setting range |
Possible to set 10 to 100% of full scale |
Alarm contact |
1C contact for each alarm |
Alarm contact capacity |
AC250 V 3.0A / DC24 V , 3.0 A (at resistive load) |
Alarm reset |
Automatic |
Operational temperature /
humidity range |
0 to 50 ゚C 0 to 85 % RH (Non-condensing) |
Power supply |
AC100 V or 110 V *2 (+10 % / -15 %), 50 / 60 Hz |
Power consumption |
15 VA or less |
Size / Mass |
200 (W) x 103 (D) x 105 (H) mm (excluding connectors etc.) / 2 kg |