WBGT Heat Stress Monitor Model SK-160GT


This is a Wall-mount/desk-top type instrument that indicates the indoor WBGT Index and the guideline with four warning levels and measures temperature and humidity. When the measured value exceeds the set WBGT index, buzzer sounds and LED lights. Atomic clock is equipped.

Features

This instrument is indoor use only.

The wet bulb globe temperature (WBGT) index integrates the three factors of air temperature, humidity and radiation heat, each of which greatly affects the heat balance of the human body. The index is normally obtained using the dry, wet and black bulb temperature measurement values.

Measurement of wet or black bulb temperature requires considerable expertise, and the equipment handling and location are limited.

The unit calculates the WBGT index by using the measured temperature and humidity, in accordance with the "Guidelines to prevent heat disorder in daily life" of the Japanese Society of Biometeorology.

The WBGT index is low when the air temperature and humidity are low, while it is high when the air temperature and humidity are high.

The risk of heatstroke increases with the WBGT index. Thus, the determined WBGT index can be used as a guideline for preventing heatstroke.

Source: "Guidelines to prevent heat disorder in daily life" of the Japanese Society of Biometeorology

[Guideline for preventing heatstroke in daily life]

WBGT Index
Risk of occurrence in relation to physical activity
Remarks
Danger
(31°C or higher)
Risk during any physical activity
Risk of occurrence is high in the elderly, even in the resting state. Avoid going out and stay in a cool room
Severe warning
(28 to 31°C)
Avoid direct sunlight outdoors and watch for any rise in room temperature indoors
Warning
(25 to 28°C)
Risk during moderate to vigorous physical activity
Regularly take adequate rest when exercising or doing vigorous work.
Caution
(25°C or lower)
Risk during very vigorous physical
Basically low in risk, but high in risk when doing vigorous exercise or heavy labor

 

Specifications

Product WBGT Heat Stress Monitor
Cat. No. 8311-00
Model SK-160GT
Measuring range WBGT Index 0 to 50 °C (calculated)
Temperature 0.0 to 50.0°C
Humidity 20.0 to 95.0%rh
Accuracy Temperature ±1.0°C (10 to 40°C)
±1.5°C (at other range)
Humidity ±5%rh (40 to 70%rh at 20 to 30°C)
±8%rh (at other range)
Resolution WBGT Index 1°C
Temperature 0.1°C
Humidity 0.1%rh
Sampling approx. 30 sec.
sensing elements Temperature Thermistor
Humidity High polymer resistance change type
Alarm setting range Available to set by 1°C step in the range of WBGT Index (0 to 50°C)
Clock Atomic clock (40kHz/60kHz Automatic reception) 12/24 hours display
Clock accuracy ±1 sec.: when the tine calculation signals is receiving
±45 sec. per month: without the time calculation signals
Operation ambient 0 to 50°C,less than 95%rh (no condensing)
Storage ambient 0 to 50°C (no condensing)
Power requirement AA size battery x 3 pcs. (4.5V)
Battery life Approx. one year (use of alkali batteries, alarm is used once a day, without manual reception of clock)
Materials (body) ABS resin, acryl resin
Dimensions approx. (W)225 x (H)165 x (D)25mm
Weight approx. 500g (includes batteries)
Accessories AA manganese battery (R6P) 3 pcs. For monitoring purpose
Instruction manual

The attached batteries are used for monitoring and the battery life may be shorter than standard.