Máy đo độ cứng cao su ASKER Durometer Type FP

Ngày đăng: 01/40/2023 - 147 lượt xem

Giá: Liên hệ
  • Xuất xứ:
  • Tình trạng:
  • Model:
  • Bảo hành:
Số lượng:

Hotline:

Hotline: 0365930441

Features

Indentor

 

Height: 2.54mm Shape: Cylindrical

Pressure foot

img

An oval shaped pressure foot(50mm x 37 mm) in contact with a specimen allows a stable measurement by placing it onto the specimen.

Hardness Tester Selection Chart

Hardness Tester Selection Chart

Our product line consists of various types of durometers applicable to specific materials as indicated in the chart above.

Type A Durometer (ASKER A type), conforming to JIS K 6253-3 is the most popular type of durometer for measuring rubber hardness.

However, verification is recommended because a significant difference is estimated to be the largest when a durometer indicates measurement values from 10 to 90 points.

For hard specimens for which Type A Durometer readings indicate more than 90 points, measurements should be undertaken using the Type D Durometer (ASKER D type). However, for soft specimens with measurements of less than 20 points, the ASKER C type or Type E Durometer (ASKER E type) should be used. The most important consideration in using durometers is to select the correct type for purposes of measurement according to the specimen.

Specification

Indication range
0 point - 100 point (262 degree dial scale)
Minimum indication
1 point (Accuracy : ±1 point)
Indentor Design (mm)
Height: 2.54 15 Dia. Cylindrical
Spring Forces [mN(g)]
0 point:
980(100)
100 point:
1960(200)
Central hole of diameter of Pressure foot
Φ16
Pressure foot Dimension (mm)
50×37(Oval shape)
Outer Dimension (mm)
Approx. Width 50×Depth 37×Height 81
Weight (g)
300
Application
Powder puff

Option

img

Two-pointer type (max-hand and active hand) of Rubber Hardness Tester

The stationary set hand (max-hand) makes the maximum value easier to read and allows the creep characteristics of a specimen.

Accurate measurement is made possible for specimens* for which stress relaxation occurs over time or for specimens for which it is difficult to take readings from the front.

*Materials for which the reading decreases immediately after the indentor has been pressed against the surface.