DF805S Features

Slim, compact, and having a high resolution of 0.1 μm maximum The maximum response speed has also further advanced.

  • Measuring range: 5mm
  • Accuracy: 1 μm
  • Maximum resolution: 0.1 μm
  • Maximum response speed: 80 m/min
  • Built-in reference point
  • Excellent resistance to water and oil
  • Adopts a flexing-resistance cable
  • Achieved numbers of strokes: 92 million (full stroke sliding test 2 years passed as of March, 2014)

MF10 Features

Simple settings make operating easy. Threshold can be set by two clicks.

  • Input/output circuit: NPN output(Current sink) / PNP output(Current source)
  • Number of Go/NoGo judgment outputs: 2
  • External input: 1
  • Minimum display unit: 0.1μm
  • Power supply voltage: 10 to 30VDC, including ripple(p-p) 10%
  • Protection circuit: Power supply reverse polarity protection, output short-circuit protection, and output incorrect connection protection
  • Number of banks: 4

Specifications

DF805S series Specifications

Magnescale reserves the right to change product specifications without prior notice.

Model DF805SR、DF805SFR DF805SLR、DF805SFLR
Measuring range 5mm
Resolution 0.1μm
Accuracy(at 20°C/68°F) 1μm
Measuring force(at 20°C/68°F) Upward:0.35±0.25N
Horizontal:0.40±0.25N
Downward:0.45±0.25N
Maximum response speed 80m/min
Reference point at 1±0.5 mm position of spindle movement
Reference point response speed 80m/min
Output Dedicated serial communication protocol
Spindle driving Spring push
Achieved number of strokes 92 million strokes (full stroke sliding test 2 years passed as of March, 2014)
Protective structure IP66/67 IP54
When a ø4 mm tube is connected : IP67
Impact resistance 100m/s2(20~2,000Hz)
Vibration resistance 1,000m/s2(11ms)
Operating temperature 0~55℃
Storage temperature -20~60℃
Power supply voltage +10 to +30V DC including ripple (p-p) 10%
Power consumption 1.2 W or less
Mass Approx. 30 g (not including cable parts and interpolation box)
Probe part cable length 2m
Output cable length Max. 20 m (Use the optional CE34.)
Feeler Provided with a carbide ball tip Mount screw M2.5
Accessories Instruction Manual, 1 wrench,
1 hose elbow (only DF8**S*L**)
Tightening nut, clamp wrench, wave washer, stop pin (1 each) (only DF8**S*F**)
MF10 series Specifications

*1. At a power supply voltage of 10 to 30 V, Normal mode: 2250 mW or less (power supply voltage 30 V: power consumption 75 mA or less / power supply voltage 10 V: power consumption 155 mA or less), power-saving ECO mode: 2100 mW or less (power supply voltage 30 V: power consumption 70 mA or less / power supply voltage 10 V: power consumption 135 mA or less)
*2. When lining up 4 or more digital tolerance indicators, the 2 output total is 20 mA or less.
*3 When used in a row, the operating ambient temperature range is 0°C to +50°C for 3 to 10 units, 0°C to +45°C for 11 to 16 units, and 0°C to +40°C for 17 to 30 units.

Magnescale reserves the right to change product specifications without prior notice.

Model MF10-P1 MF10-P2
Type I/O circuit NPN output (current sink) PNP output (current source)
I/O Number of Go/NoGo judgment outputs 2
Number of external inputs 1
Minimum display unit 0.1μm
Power supply voltage +10 to +30V DC including ripple (p-p) 10%
Power consumption*1 Power supply voltage 24 V normal mode: 2040 mW or less (Power consumption 85 mA or less)
Power-saving ECO mode: 1920 mW or less(Current consumption 80 mA or less)
Go/NoGo judgment output*2 Load voltage: DC 30 V or less, open collector output type
Load current: the total of the two outputs must be 100 mA or less
Residual voltage and load current less than 10 mA: 1 V or less
Load current 10 mA to 100 mA: 2 V or less
Off-state current: 0.1 mA or less
Protection circuit Power supply reverse connection protection, output short-circuit protection and output reverse connection protection
Number of banks 4 (Can be set 4 kinds of judgment value)
Ambient temperature range*3 Operating: When lining up 1 or 2 digital tolerance indicators: 0°C to +55°C
Storage: -10°C to +60°C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% RH (with no condensation)
Mass (main unit) Approx. 75 g
Cable length 2m