Bộ nguồn Simco XP/XPM

Ngày đăng: 23/33/2019 - 796 lượt xem

Giá: Liên hệ
  • Xuất xứ:
  • Tình trạng:
  • Model:
  • Bảo hành:
Số lượng:

Hotline:

Hotline: 0365930441

XP Series

The XP167 (120V) and XP267 (230V) are UL listed for use in Class I, Division 1 and 2, Group D Hazardous Locations when used with XP-20F Blowers.

The power supplies are equipped with an arc detection cut-off circuit with alarm capability. In the unlikely event that the static eliminator or cable should arc to ground, the arc detection circuit senses the short and shuts down the power supply within 40 milliseconds. The units include relay contacts that can be used to activate a remote visual or audio alarm and to trigger a PLC, for instance, to shut down the line.

The XP Power Supplies can be mounted within the hazardous location.

XPM Series

The XPM167and XPM267 Power Supplies are UL/CUL approved for mounting outside of a hazardous location. The XPM167 has an arc detection circuit to shut down the power supply within 40 milliseconds in the event of an arc from the blower or cable. Includes a monitoring system, when operated with the XP-20F, to detect arcing conditions and short circuit on the ionizing points and the cable. Indicator lamps verify input and output voltage status as well as arc detection. Integrated relay contacts allow for remote monitoring of these features.

Specifications

XP167

 
Input Requirements 120V, 60 Hz
Output Voltage 7 kV, 3mA max
Number of outputs for static eliminators 4
Max Length of static bars which can be attached 300 inches
Does the unit accept shielded cable N/A
Acceptable for hazardous locations Yes

XP267

 
Input Requirements 230V, 60 Hz
Output Voltage 7 kV, 3mA max
Number of outputs for static eliminators 4
Max Length of static bars which can be attached 300 inches
Does the unit accept shielded cable N/A
Acceptable for hazardous locations Yes

XPM167

 
Input Requirements 120V, 60Hz
Output Voltage 7kV, 3mA max
Number of outputs for static eliminators 4
Max Length of static bars which can be attached 300 inches
Does the unit accept shielded cable Yes
Acceptable for hazardous locations No

XPM267

 
Input Requirements 230V, 60Hz
Output Voltage 7kV, 3mA max
Number of outputs for static eliminators 4
Max Length of static bars which can be attached 300 inches
Does the unit accept shielded cable Yes
Acceptable for hazardous locations See Overview

Part Numbers:

 
XP167 4009088
XP267 4009089
XPM167 4009064
XPM267 4009065