For measurements and control in diverse field uses. Multifunction counter with RS-232C interface

  • RS-232C standard function
  • Peak Hold Function Convenient for Statistical Measurement
  • Convenient External Input Functions for Automatic Measurement
  • Display Resolution Switching
  • Data Storage
  • Reset/Preset/Restart
  • Detecting Reference Point of Measurement Unit
  • Scaling Flicker Control

Specifications

Specifications

Magnescale reserves the right to change product specifications without prior notice.

Model LY72
Specifications by application Applications as gauge (set axis labels A, B, and C) Applications as scale (set axis labels X, Y, and Z)
Number of input shafts 1~3axis
Display 7 digits and minus display, Color amber
Display data Current (1st axis, 2nd axis, addition axis), maximum, minimum and peak-to-peak values Current (1st axis, 3rd axis, addition axis)
Input resolution
  • Standard : 0.1 μm, 0.5 μm, 1 μm, 5 μm, 10 μm, 1 s, 10 s, 1 min, 10 min
  • Expanded : 100 μm, 50 μm, 25 μm, 20 μm, 2 μm, 0.05 μm, and 1 degree can be added.
Display resolution Measuring unit input resolution or higher and supported inch units
Input signal A/B quadrature signal, Z signal (Conforms to EIA-422)
AlarmDisplay Measuring unit disconnected, Excess speed, Maximum display amount exceeded, Power failure, Error in stored data
Reset Current value reset, Alarm cancel
Restart Restart of peak value calculation for each axis/all axes -
Preset It is possible to store/edit up to three values for each axis.
Master calibration function The master calibration value is relocated when going past the reference point after the power is turned on. -
Reference point operations It is possible to store/edit one value for each axis (when not using the master calibration function).
Hold function
  • Selectable from latch and pause
  • Latch : Display held while latched (Display hold)
  • Pause : Peak calculation stopped while paused (Peak calculation hold)
Display hold
Linear compensation A fixed compensation amount is applied to the measuring unit's count value. Compensation amount Standard: ±600 μm/m (Expanded: ±1000 μm/m)
Scaling 0.100000~9.999999
I/O  
  • Data format : All axes on same line/New line for each axis Peak-to-peak value
  • Transfer rate:38400/19200/9600/4800/2400/1200bps
  • Parity : None/Odd/Even, Stop bit : 1 or 2, Data length : 8 bits or 7 bits
Timer output OFF/0.2/0.5/1/5/10/30/60/300秒
Output data Current value/Maximum value/Minimum value Peak-to-Peak value Current value
Power supply DC 12 V Rating 0.75 A Max. 1 A AC 100 V to 240 V ±10 % When using the AC adaptor PSC-22 (For U.S. only) or PSC-23 (For Europe and other countries) *Option
Power consumption MAX. 32 VA connected at the AC adaptor.
Temperature Operating : 0~40℃(non condensing), Storage : -20~60℃(non condensing)
Mass Approx. 1.5kg
 
 